MiljöEko3® - a cast-resin-insulated transformer that exceeds current legal requirements!

Technology and the Environment for the Future

We’re not just sitting around waiting for new laws and regulations to take effect. We are in constant dialogue with our suppliers and engineers about how to improve our products, both in terms of quality and environmental impact. When we saw that several reports and studies pointed toward even stricter requirements for power losses in transformers within the EU, we decided to take action now. That is why we developed a new series of transformers that meet the requirements being discussed in preparation for a potential Phase 3 of the Ecodesign Directive*. The result was MiljöEko3®.

*At this stage, discussions are only ongoing for a possible phase 3 of the Ecodesign Directive. We therefore do not guarantee that the product meets requirements that have not yet been established.

Reduce operating costs and future-proof your facility

MiljöEko3® is our next step toward more energy-efficient dry-type transformers. With 10% lower no-load losses than our MiljöEko2® cast resin transformer, you’ll enjoy lower energy losses and lower operating costs, while also preparing for the stricter requirements currently under discussion.

The reduced energy costs mean that the additional investment in MiljöEko3® can pay for itself in just a few years. After that, you’ll continue to save money for the remainder of the transformer’s service life. How much you can save depends, among other things, on the transformer’s load. Using our calculation tool, you can enter your own parameters and see the difference in energy costs over the transformer’s service life.

Calculate and compare energy losses and costs for MiljöEko3®

Technical Data - MiljöEko3®

Effect100kVA - 3150kVA
Design voltage12, 24 kV
Ambient temperature-60°C till +60°C
Winding materialAluminium or Copper
Insulation materialCast resin
Enclosure classesIP00 to IP56
AccessoriesTemperature sensors, PT100 sensors, fans for forced cooling, vibration dampers, grounding terminals, etc. See also Webshop in the Product Menu
ClassificationE2, C2, F1 is standard. For other classifications, please contact us.
CoolingAN / ANAF / AFWF
Frequencies50 Hz, 60 Hz, 16 2/3 Hz
Partial discharges<10 pC
Image

This is MiljöEko3®

  • A series of cast-resin transformers developed with future requirements in mind, based on ongoing discussions regarding Phase 3 of the Ecodesign Directive.​​
  • Lower power losses for a better environment.​
  • The investment pays for itself in a few years, as it has a service life of 35–40 years—and likely even longer.​
Contact us for more information