Tekniska data
Brandsäker termoplast | UL94-V0 |
Frekvensområde | 50÷60 Hz |
min. rated burden | 3VA |
insulation reference voltage | 0,72 kV |
Testspänning | 3 kV x 1’ 50 Hz |
Tempklass | E |
Skyddsklass | IP 20 |
continuous overcurrent | 1,2 In |
rated short-time thermal current (I th) | 60 In |
rated dynamic current (I dyn) | 2.5 x I th |
Säkerhetsfaktor | N ≤5 |
max. power dissipation (max range value) | ≤ 2W |
operating temperature | -25 +50 °C |
storage temperature | -40 +80 °C |
Tillverkningsstandard | IEC/EN 61869-1, IEC/EN 61869-2 |
integrated secondary terminals | 6 mm² |
BELASTNING VA | |||
OMSÄTTNING | KLASS 0,5 | KLASS 1 | ARTIKELNUMMER |
5/1 A | 5 | 7 | TAC005005X01 |
10/1 A | 5 | 7 | TAC005010X01 |
15/1 A | 5 | 7 | TAC005015X01 |
20/1 A | 5 | 7 | TAC005020X01 |
25/1 A | 5 | 7 | TAC005025X01 |
30/1 A | 5 | 7 | TAC005030X01 |
40/1 A | 5 | 7 | TAC005040X01 |
50/1 A | 5 | 7 | TAC005050X01 |
60/1 A | 5 | 7 | TAC005060X01 |
80/1 A | 5 | 7 | TAC005080X01 |
100/1 A | 5 | 7 | TAC005100X01 |
5/5 A | 5 | 7 | TAC005005X05 |
10/5 A | 5 | 7 | TAC005010X05 |
15/5 A | 5 | 7 | TAC005015X05 |
20/5 A | 5 | 7 | TAC005020X05 |
25/5 A | 5 | 7 | TAC005025X05 |
30/5 A | 5 | 7 | TAC005030X05 |
40/5 A | 5 | 7 | TAC005040X05 |
50/5 A | 5 | 7 | TAC005050X05 |
60/5 A | 5 | 7 | TAC005060X05 |
80/5 A | 5 | 7 | TAC005080X05 |
100/5 A | 5 | 7 | TAC005100X05 |